Air Conditioner | Doesn’t Work At All

If your central air conditioner doesn’t go on automatically when the thermostat signals the need for cooling, it’s quite likely that the thermostat isn’t working properly or the unit is receiving electrical power. Before you do anything else, be sure the thermostat is set to COOL and its temperature setting is well below the ambient temperature.
Then do the following:

1. Check the main electrical panel and any secondary circuit panels for a tripped breaker or blown fuse. If you find the problem there, reset the breaker or replace the fuse. A central air conditioner should be on a dedicated 240-volt circuit.

2. Make sure the furnace power switch is turned on and that the outdoor condenser’s power switch, which is mounted on the outdoor unit, hasn’t been shut off. Also be sure the 240-volt disconnect next to the compressor, which is in a metal box usually mounted on the house wall, hasn’t been shut off.

3. Turn off the power to the air conditioner and check the thermostat. Remove the thermostat’s cover and unscrew the wire from the Y terminal. Turn the power back on. Holding the wire by its insulation only, touch the bare end to the R terminal and hold it there for about two minutes. If the compressor kicks on, the thermostat is faulty; replace it or call an air-conditioning technician. If the compressor doesn’t go on when you hold the two wires together, turn the power back off and call an AC technician.- Don Vandervort, HomeTips

AIRMAX Heating & Air operates 24 hours a day, always ready to assist you with any heating and cooling needs you may have. We are a family owned Air Conditioning & Heating business and offer a Comprehensive HVAC Service in Charleston, Berkeley, Dorchester as South Carolina’s Top Choice!.

Call today for an estimate! (843) 614-3276